溫濕度循環(huán)試驗箱循環(huán)試驗失效原因解析
溫濕度循環(huán)試驗箱 又名“高低溫交變濕熱試驗箱”,采用kw-890型lcd觸摸屏智能型儀表,可設(shè)定程序循環(huán)試驗,在試驗進行階段,有一種循環(huán)試驗失效,下面由恒溫恒濕試驗箱生產(chǎn)專家-東莞市科文試驗設(shè)備有限公司對失效原因進行分析:
constant temperature and humidity test chamber also known as high low temperature alternating test chamber, based on inligent instrument, screen can be set program loop test, in test phase, there is a cycling test fails, the following by the constant temperature and humidity test chamber production experts - dongguan kowintestequipment co., ltd., analyzes the failure reason:
1, the basic parameters: the temperature cyclic stress mainly has six basic parameters:
1、溫度循環(huán)應(yīng)力基本參數(shù):基本參數(shù)主要有6個:①上限溫度;②下限溫度;③溫度變化速率;④上限溫度保溫時間;⑤下限溫度保溫時間;⑥循環(huán)次數(shù)。
(1) ceiling temperature;
(2) the lower temperature;
(3) temperature change rate;
(4) limit temperature holding time;
(5) the lower temperature holding time; 6 cycles.
2、溫度循環(huán)應(yīng)力特性分析:在溫度循環(huán)試驗中,恒溫恒濕試驗箱內(nèi)的氣流均勻度是一個很重要的參數(shù),該參數(shù)將影響產(chǎn)品的溫度變化速率。這就要求在多個試驗產(chǎn)品同時進行試驗時,試驗產(chǎn)品之間、試驗產(chǎn)品和試驗箱壁之間應(yīng)有適當?shù)拈g隔,以便氣流能在試驗產(chǎn)品之間、試驗產(chǎn)品和箱壁之間自由循環(huán)。
2, temperature cycle stress characteristic: in the temperature cycling test, constant temperature and humidity test in the airflow uniformity is an important parameter, this parameter will influence the temperature change rate of the products.
3、溫度循環(huán)應(yīng)力誘發(fā)失效的機理及敏感元件:溫度循環(huán)使不同膨脹系數(shù)的不同材料的膨脹情況不同,造成剝離、開裂、其敏感元件如油漆涂覆層等。
3.1溫度循環(huán)使螺絲連接或鉚接不牢的接頭松馳,其敏感元件如螺絲、鉚接部件等;
3.2溫度循環(huán)使機械張力不足的壓配接頭松馳;高低溫交變試驗箱溫度循環(huán)使材質(zhì)差的釬焊接觸電阻加大或誘發(fā)開路,其敏感元件如電阻元件等;
3.3溫度循環(huán)使觸點腐蝕和污染,其敏感元件如合金材料等。
東莞市科文試驗設(shè)備有限公司專業(yè)生產(chǎn):溫濕度循環(huán)試驗箱;溫濕度試驗箱;溫濕度老化試驗箱;溫濕度交變試驗箱;可程式溫濕度試驗箱;溫濕度循環(huán)測試箱等產(chǎn)品,并為客戶提供優(yōu)惠的溫濕度循環(huán)試驗箱價格。如需了解溫濕度老化試驗箱更多技術(shù)資訊請您登錄溫濕度循環(huán)試驗箱廠家科文http://